Conventional Fire System Panels RE-104-4 Zones

Overview

The microprocessor based 4 Zone CE mark conventional fire alarm control panel is a standalone system, with 16 X 2 LCD character, 4 zones detection circuit,3 common potential free contacts & a common NAC sounder output, wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection.




Special Feature

Ravel Indian Manufacturer, International standard.
Switch Mode Power Supply.
Modular Construction, Serviceable.
Surface Mount Technology.
Battery polarity & deep discharge protection.
As per IS -15908: 2011 Standard.
16 X 2 Dot Matrix LCD Display.
Standby battery backup with built in charging.
Fire / Fault status in unambiguous colored LED indication.
Switch Mode Power Supply.
Tactile Keypad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility
Zone wise one man walk Test Facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all type of Conventional Detectors.
Optional Zone Wise Sounder / Zone Wise Contact.

Tech Specification

Electrical Specification                 

Primary Power

120 – 220VAC , 50 Hz

Common Relays

Type                                       :  Form C
No of Relays                          :   3
Relay Contact Rating           :  2Amps @ 30 VDC, 0.5Amps @125VAC.
Power Factor   

Standby Power

24V D.C (2 Nos of 12v, 7Ah Sealed Lead acid battery).
Quiescent current   :   55mA         

Operating Condition

Operating Temperature   :   0 – 49° C/32-120° F.
Relative Humidity            :   93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F.

Initiating Device Circuits (Zone Circuit)

All zones are Class B wiring
Normal Operating Voltage   :   14- 21 VDC
Alarm Current                      :   15 – 30mA
Short Circuit Current          :   42mA Maximum
Loop resistance                     :   50 ohms Maximum
End-Of-Line Resistor          :   4.7K, 1/4watt
Standby Current                  : 6.8mA (2.4mA for Detectors)

Charging Circuit

Charging Voltage 28.2V, ±0.5V
Charging Current 0.5 A (Max.).  

Notification Appliance Circuits

Class B wiring
Operating Nominal Voltage   :   24VDC
Current for NACs   :   0.6 Amp
End-Of-Line Resistor   :   4K7, 1/4 watt
Mechanical Specification
Dimensions                              (350W X 250H X 100D)
Color                                         Red / White
Construction                             18 Gauge (1.22mm) CRCA sheet with powder-coated Finish
IP Rating                                  IP50
Cable Entry                             11xø19mm Knockout in top of the cabinet

Ordering Information

Model
Description
RE-104-R
4 ZONE Fire Alarm Panel
RE-104-W
4 ZONE Fire Alarm Panel
 
Note:

R- Red Color, W-White Color
Compatible Devices

Model
Description
RE-316S-2L
Photoelectric Smoke detector with base.
RE-316H-2L
Heat detector with base.
RE-316SH-2L
Photoelectric & Heat detector with base